                                How to Diagnosing Units SSC WE Service Level
 Maintaining commercial kitchen equipment helps keep your kitchen and best to be familiar with the   restaurant and Hotel equipment by reviewing the owner's manual to Contact a professional repair   technician to conduct regular planned.The Rational Self Cooking Center not only makes cooking   easy, but it also has some helpful features for technicians who service the equipment. Perhaps one of   the best features is the machine’s ability to offer diagnostic codes. Each code will tell you what’s   wrong with the oven, allowing you to tackle the issue quicker.
 What’s was faulty appearing? Unit runs in emergency humidity control
 Remedy?? Humidity control is out of function and needs to be repaired or replaced
 Service 31
 What’s was faulty appearing? Faulty core probe
 Probes (x):
 31.1: Shaft probe
 31.2: Fifth probe (near shaft)
 31.4: Fourth probe
 31.8: Third probe
 31.16: Second probe
 31.32: First probe in tip
 COMBINATION OF FAULTY PROBES CAN DISPLAY (EXAMPLE: FAULTY FOURTH AND   THIRD PROBE WILL DISPLAY AS “31.12″)
 Remedy? Repair or replace the faulty probe
 Service 32 1-2
 What’s was faulty appearing? Faulty ignition box
 Ignition boxes:
 32.0: Ignition box top
 32.1: Ignition box bottom (floor models only)
 32.2: Both ignition boxes
 Remedy? Change the ignition box that appears in error code
 Service 33 1-2
 What’s was faulty appearing? Faulty ignition box
 Ignition boxes:
 31.1: Ignition box bottom (floor models only)
 31.2: Both ignition boxes
 Remedy? Check the ignition wiring or ignition box gas valve and supply
 Service 34
 What’s was faulty appearing? Bus signal problems
 Probes (x):
 34.1: Motor top
 34.2: Motor bottom
 34.4: Ignition module top
 34.8: Ignition module bottom
 COMBINATION OF BUS SIGNAL PROBLEMS CAN DISPLAY (EXAMPLE: IGNITION   MODULE TOP AND BOTTOM WILL DISPLAY AS “34.12″)
 Remedy? See if the bus cable plug and cable connection are connected or damaged
 Service 35
 What’s was faulty appearing? Bus signal can’t be processed due to disconnected ultravent
 Remedy?? Connect the ultravent
 Service 36
 What’s was faulty appearing?Defective differential pressure sensor P1
 Remedy?? Repair or replace the sensor
 Service 37
 What’s was faulty appearing? Differential pressure sensor P1 isn’t in expected range
 Remedy?? Check the connection of hoses
 Service 40
 What’s the cause? Care pump is broken or doesn’t fill enough solution into the steam generator
 Remedy?? Check if the hose from the care pump outlet isn’t kinked and reset error by   completed a successful rinse program
 Service 41
 What’s was faulty appearing? Defective solenoid valve Y3, blocked moistening valve or CDS   isn’t sending pulses
 Remedy?? Resolve issue and reset error by completed a successful rinse program
 Service 42
 What’s was faulty appearing? Defective solenoid Y4 Care, hose to Care container   blocked/kinked or CDS isn’t sending pulses
 Remedy?? Resolve issue and reset error by completed a successful rinse program
 Service 43
 What’s was faulty appearing?Solenoid Y1, Y3 or Y4 is passing water/won’t close and CDS is   always sending pulses
 Remedy?? Reset error by completed an abort program
 Service 44
 What’s was faulty appearing? Steam not heating during CleanJet+Care
 Remedy?? Reset error by completed an abort program
 Service 60
 What’s was faulty appearing? Incorrect initialization of ignition box?
 Remedy?? Check the gas settings and switch the unit off and on again before running SD   Repair program?
 Service 63
 What’s was faulty appearing? Self-test running without water
 Remedy?? Allow the unit to cool down and see if? B1, B2 and B4 are below 104?F (40?C); Set   Selftest to ON and switch unit off and on
 again before running Selftest
 Service 100
 What’s was faulty appearing? Defective SC pump or calcified level electrode
 Remedy? Reset error by completed an abort program
 Service 120
 What’s was faulty appearing? Defective Care pump M12 or level electrode
 Remedy? Reset error by completed an abort program




Machine Spare Parts Manual's
 Rational Parts  / MKN Parts / Conveothem Parts / Inoxtrend parts / Fagoor Parts / True Parts
 Rational Vario Cooking Parts / Meiko Dishwasher Parts / Alto Shaam Parts
 Vario Cooking Rational Software Update's / Amana Parts / Menumaster Parts / Merrychef Parts
 Ice O Matic Parts / Blender Robot Coupe Parts / Comenda Parts / Blender Waring Parts 
 Ice Machine Scotsman parts / Hozhizaki Ice Machine Parts / Hobart Dishwasher Parts 


Post a Comment

0 Comments