This button is multi-functional and indicates the current operating status through different colours
Machine ON
Pressing this button for approx. 3 seconds switches on the machine.
Transport ON
Pressing this button when the machine is switched on, filled and operational starts the transport operation.
Speed alteration
Pressing this button when the transport function is activated alters the speed. The LEDs 7 indicate the selected speed.
Machine OFF
Pressing this button for approx. 5 seconds switches off the machine. Exhaust air blower and dryer blower may run on. After switch off, the machine is not voltage free! A dot is lit in the display field.
• Flashing green = machine is being filled and heated
• Green = machine is operational
• Blue = wash mode
• Flashing blue = machine is drained
• Red = critical fault
• Green/red alternating = uncritical fault
• Blue/red alternating = uncritical fault
• Green/ blue alternating = pre-washing is being drained and filled
Fault Code |
Designation description | ||||||||
---|---|---|---|---|---|---|---|---|---|
E001 | Fill time exceedance break tank | If the solenoid valve is actuated for the first time after "Machine on", the time until the float switch 1B1 responds is measured – if this time exceeds the preset time C01, the fault message is displayed. | |||||||
No water supply in break tank? | On site shut-off valve not opened On site filter clogged, filter or reducer upstream of solenoid valve clogged Solenoid valve does not open Output of control card defective |
||||||||
No signal at the control input | Float switch defective Float switch incorrectly fitted |
||||||||
E002 | Fill time exceedance break tank | If the float switch has already switched for the first time (= break tank was full), the switching hysteresis is from now on monitored via C02. If the response time of the float switch > C02, the fault message is displayed. |
|||||||
If the fault lasts longer than C01, Err 001 is generated! Display changes to RED/ DURATION | |||||||||
Supply quantity too low? | On site water pressure too low On site filter clogged On site shut-off valve not completely open Filter or reducer upstream of solenoid valve clogged Solenoid valve does not open completely Output of control card defective |
||||||||
Removal volume too high? | Rinse arm not in position Leak in final rinse system Leak O-ring rinse arm holder Spray nozzle has dropped from rinse arm |
||||||||
E003 | Fill start temperature hot water tank not reached | If at fill start the temperature F01 is not reached within time C37, the fault mes- sage is displayed. | |||||||
Hot water tank does not heat up | Hot water tank heater defective Hot water tank heater contactor defective |
Fault Code |
Designation description | |||||
---|---|---|---|---|---|---|
E004 | Temperature shortfall Hot water tank |
If the temperature falls short of tempe- rature F15 for a time >= C06, the fault message is displayed. | ||||
Heat output missing? | Curtains not in position Phase missing on feed cable, motor protection switch or contactor Heater defective Wire jumper on heater missing |
|||||
Water consumption too high? | Rinse arm not in position Leak in final rinse system Leak O-ring rinse arm holder Spray nozzle has dropped from rinse arm Wrong diaphragm installed or setting of manual valve changed |
|||||
E005 | Fill time exceedance tanks | If tank filling is not completed within C38, the fault message is displayed. | ||||
Supply quantity too low? | On site water pressure too low On site filter clogged On site shut-off valve not completely open Filter or reducer upstream of solenoid valve clogged |
|||||
Water in tank disappears? | Foreign particles in drain valve Drain valve seal defective |
E006 | Temperature shortfall "AR segment" |
If the temperature falls short of tempe- rature F14 for a time >= C06, the fault message is displayed and transport is stopped! | ||||
---|---|---|---|---|---|---|
Heat output missing? | Curtains not in position Wash arms not in position Water entrainment by washware Phase missing on feed cable, motor protection switch or contactor Heater defective Wire jumper on heater missing |
|||||
E007 | Interruption safety chain 1A1 | Input 1A1/X13.1-2 open | ||||
– Doors open – Motor protection switch transport has tripped – Blockage transport switch has tripped – additionally on FTN and FUX motor protection switch washing, etc. |
||||||
E008 | Interruption safety chain 2A1 | Input 2A1/X13.1-2 open | ||||
Wire jumper missing |
NEXT PAGE👆
Fault Code |
Designation description | |||||
---|---|---|---|---|---|---|
E009 | Limit switch of table or rake actuated | Input 1A1/X12.1-4 opened | ||||
– Table limit switch CN defective – Light sensor/barrier CN defective – Limit switch rake 2S5 FTN defective |
||||||
E010 | Heat pump CHP18 high pressure fault | If a high pressure fault occurs four times within time span C26, the fault message is displayed. Occurrence of the fault messages is recorded in the separate counter C65. |
||||
Water entrainment as curtains are not in position or missing Water entrainment as wash arms are not in position Water entrainment by wash ware (wrong loading) Foaming in the wash tank Inlet water missing or temperature higher than 25° C Tank circulation pump defective Float switch defective or heavily soiled Foreign particles in the drain valve Seal of drain valve defective Switch-off temperature AR tank set too high Temperature sensor defective or wrong offset Primary energy too high due to dryer |
||||||
E011 | Heat pump CHP18 low pressure fault | If a low pressure fault occurs four times within time span C26, the fault message is displayed. Occurrence of the fault messages is recorded in the separate counter C66. |
||||
Inlet temperature filling lower than 45° C Coverings CHP18 open Exhaust air blower defective Lack of refrigerant Bottleneck in refrigerant circuit Heat exchanger heavily soiled Evaporator heavily soiled |
||||||
E012 | Processing fault | If "emptied" is not signalled by all tank float switches within time C39, the fault message is displayed | ||||
Water in tank? | Drain valve/drain system clogged Drain valve defective |
|||||
No water in tank? | Float switch stuck Float switch defective |